Configuration

Electrical systems

DC-N2K-01 — Common supply feeding both segment injections

← Circuit Register · NMEA 2000 network

Owner-confirmed functional supply, 6 November 2026; not independently electrically surveyed.

FieldRecord
Circuit IDDC-N2K-01
Destination / functionCommon supply feeding both segment injections
Known protectionCommon 10 A NAV INSTR CB-007
SourceMain DC panel; detailed upstream connection not traced
SwitchingA and B share CB-007; any additional downstream switching unconfirmed
Historical connection referenceSplit point not yet identified
Local protectionAdditional downstream fuses not yet established
Wiring / returnSplit point, injection hardware, conductor sizes, lengths and negative-return route untraced

See DC-N2K-01 for the common supply, DC-N2K-02 for A and DC-N2K-03 for B. These circuit IDs do not imply additional breakers or verified protection coordination. Positive-supply separation at EQ-063 is distinct from shared upstream supply/protection.

DC-N2K-02 — Segment A power injection behind DCP

← Circuit Register · NMEA 2000 network

Owner-confirmed functional supply, 6 November 2026; not independently electrically surveyed.

FieldRecord
Circuit IDDC-N2K-02
Destination / functionSegment A power injection behind DCP
Known protectionCommon 10 A NAV INSTR CB-007
SourceMain DC panel; detailed upstream connection not traced
SwitchingA and B share CB-007; any additional downstream switching unconfirmed
Historical connection referenceHistorical R1 / NMEA 2K A — continuity untraced
Local protectionAdditional downstream fuses not yet established
Wiring / returnSplit point, injection hardware, conductor sizes, lengths and negative-return route untraced

See DC-N2K-01 for the common supply, DC-N2K-02 for A and DC-N2K-03 for B. These circuit IDs do not imply additional breakers or verified protection coordination. Positive-supply separation at EQ-063 is distinct from shared upstream supply/protection.

DC-N2K-03 — Segment B power injection behind DCP

← Circuit Register · NMEA 2000 network

Owner-confirmed functional supply, 6 November 2026; not independently electrically surveyed.

FieldRecord
Circuit IDDC-N2K-03
Destination / functionSegment B power injection behind DCP
Known protectionCommon 10 A NAV INSTR CB-007
SourceMain DC panel; detailed upstream connection not traced
SwitchingA and B share CB-007; any additional downstream switching unconfirmed
Historical connection referenceHistorical Y1 / NMEA 2K B — continuity untraced
Local protectionAdditional downstream fuses not yet established
Wiring / returnSplit point, injection hardware, conductor sizes, lengths and negative-return route untraced

See DC-N2K-01 for the common supply, DC-N2K-02 for A and DC-N2K-03 for B. These circuit IDs do not imply additional breakers or verified protection coordination. Positive-supply separation at EQ-063 is distinct from shared upstream supply/protection.

DC-WIN-02 — Windlass foredeck control circuit

← Circuit Register · Windlass power circuit · Windlass EQ-061

Owner-confirmed function, control supply untraced: Two separate switches mounted on the foredeck, SW-003 and SW-004, command contactor EQ-062, which operates the Lewmar HX1 800 W motor EQ-061. This is a low-current functional control relationship, separate from high-current motor supply DC-WIN-01.

AttributeCurrent documentation
Logical control circuitDC-WIN-02
Operator inputsTwo separate foredeck switches SW-003 and SW-004, exact UP/DOWN mapping not yet established
Controlled deviceEQ-062 windlass contactor
Controlled loadEQ-061 Lewmar HX1 800 W
Control source and returnUnknown; no traced fuse position, earth return, terminal number or wire colour
Installed control fuseUnknown; manufacturer standard circuit shows 3 A fuse, not established fitted
Installed control cableUnknown; Lewmar standard suggests 1.5 mm² switch wiring, not an as-fitted observation
Other control stationsNot established by owner evidence; do not assume absent

The shared SW-002 is the upstream high-current common battery-switching function, not one of the two foredeck contactor switches. The 70 A CB-006 protects the windlass motor supply, not a confirmed 70 A control circuit.

Circuit Register

Status: owner-confirmed, not independently tested. Circuit identities are distinct from equipment and physical locations.

CircuitPrimary protectionDestinationSurvey status
DC-COM-01CB-003 10 A, panel 3,4 (VHF AIS)EQ-057 four-way COM-frame fuse boardOwner-confirmed; feeder cable untested
DC-COM-02FU-001 10 A, EQ-057 way 1EQ-003 Icom M510 VHFOwner-confirmed branch protection; conductor not surveyed
DC-COM-03FU-002 3 A, EQ-057 way 2EQ-005 Digital Yacht SPL2000Owner-confirmed branch protection; conductor not surveyed
DC-COM-04FU-003 3 A, EQ-057 way 3EQ-004 Ocean Signal ATB1Owner-confirmed branch protection; conductor not surveyed

House-bank primary DC distribution

Source: The complete House bank remains one interface EQ-059. The owner confirms fitted battery-post MRBF fuses and ANL distribution fuses, with one common SW-002 for House, Autopilot and Windlass; Watchkeeper and both pumps bypass it. Windlass also retains a fitted 70 A breaker CB-006. Current ANL fuse ratings, positions and six-service mapping remain unverified. Distribution diagram.

DC-BIL-01 — Pump 1 — unswitched supply

← Circuit Register · House-bank supply diagram

Owner-reported circuit purpose; electrical installation not independently surveyed. Owner confirms a distinct unswitched pump feed; pump model, fuse, size and routing to load unverified.

FieldRecord
CircuitDC-BIL-01
SourceBB-003 positive distribution
Function / destinationPump 1, physical motor and control association to EQ-030 unresolved
Functional controlUnswitched by House/Autopilot remote controls; independent local/automatic pump control may exist
Installed branch fuse / breakerUnknown; not inferred from historical engineering proposals
Source protection / isolationUnknown; input connection to source and upstream protection not surveyed
Cable and return pathConductor size, route, overcurrent coordination, negative return through the BMV-712 system-side shunt terminal unverified

This circuit is a functional link, not evidence that a correctly rated protective device has been inspected. The service’s switching state, its fusing and its protective role are independent properties. The unswitched circuits remain live while the House or Autopilot remotely switched feeds are OFF; do not interpret unswitched as unprotected.

DC-BIL-02 — Pump 2 — unswitched supply

← Circuit Register · House-bank supply diagram

Owner-reported circuit purpose; electrical installation not independently surveyed. Owner confirms a second unswitched pump feed; pump model, fuse, size and routing to load unverified.

FieldRecord
CircuitDC-BIL-02
SourceBB-003 positive distribution
Function / destinationPump 2, physical motor and control association to EQ-031 unresolved
Functional controlUnswitched by House/Autopilot remote controls; independent local/automatic pump control may exist
Installed branch fuse / breakerUnknown; not inferred from historical engineering proposals
Source protection / isolationUnknown; input connection to source and upstream protection not surveyed
Cable and return pathConductor size, route, overcurrent coordination, negative return through the BMV-712 system-side shunt terminal unverified

This circuit is a functional link, not evidence that a correctly rated protective device has been inspected. The service’s switching state, its fusing and its protective role are independent properties. The unswitched circuits remain live while the House or Autopilot remotely switched feeds are OFF; do not interpret unswitched as unprotected.

DC-COM-01 — COM-frame feeder

← Circuit Register · COM frame

Owner-confirmed feeder, not independently traced.

PropertyValue
SupplyEQ-001 main Moody DC panel
ProtectionCB-003, 10 A, physical 3,4, label VHF AIS
DestinationEQ-057 four-way fuse board, SL-COM
Protected branchesDC-COM-02 via FU-001 (10 A VHF); DC-COM-03 via FU-002 (3 A SPL2000); DC-COM-04 via FU-003 (3 A ATB1)
Feeder cable and returnGauge, length, terminations and upstream source unverified

This circuit’s CB-003 protection covers the feeder to EQ-057. The individual downstream branch fuses are now identified as FU-001–FU-003 (ways 1–3), with ratings 10 A / 3 A / 3 A; their conductors and characteristics still require survey. Confirm feeder conductor sizing, actual breaker specification and protection coordination during the winter 2026–27 panel refit.