Circuit Register

Status: owner-confirmed, not independently tested. Circuit identities are distinct from equipment and physical locations.

CircuitPrimary protectionDestinationSurvey status
DC-COM-01CB-003 10 A, panel 3,4 (VHF AIS)EQ-057 four-way COM-frame fuse boardOwner-confirmed; feeder cable untested
DC-COM-02FU-001 10 A, EQ-057 way 1EQ-003 Icom M510 VHFOwner-confirmed branch protection; conductor not surveyed
DC-COM-03FU-002 3 A, EQ-057 way 2EQ-005 Digital Yacht SPL2000Owner-confirmed branch protection; conductor not surveyed
DC-COM-04FU-003 3 A, EQ-057 way 3EQ-004 Ocean Signal ATB1Owner-confirmed branch protection; conductor not surveyed

House-bank primary DC distribution

Source: The complete House bank remains one interface EQ-059. The owner confirms fitted battery-post MRBF fuses and ANL distribution fuses, with one common SW-002 for House, Autopilot and Windlass; Watchkeeper and both pumps bypass it. Windlass also retains a fitted 70 A breaker CB-006. Current ANL fuse ratings, positions and six-service mapping remain unverified. Distribution diagram.

CircuitInstalled protective evidenceFunctional destinationSwitching / outstanding detail
DC-PWR-01Battery-post fuses owner-confirmed installed; 2025 design specified 2 × 125 A MRBFEQ-059 → BB-003Current count, rating and cabling not inspected
DC-WAT-01ANL fuse installation confirmed as a group; particular fuse/rating not yet mappedWatchkeeperUnswitched by SW-002
DC-BIL-01Pump circuit protection untracedPump 1Unswitched by SW-002
DC-BIL-02Pump circuit protection untracedPump 2Unswitched by SW-002
DC-HOU-01Original ANL installation owner-confirmed; fuse allocation not yet tracedMain DC panel EQ-001Shares SW-002 with Pilot and Windlass
DC-PIL-01Original ANL installation owner-confirmed; individual branch protection not yet mappedAutopilotShares SW-002 with House and Windlass
DC-WIN-01CB-006 fitted 70 A breaker plus installed ANL scheme (2025 design called for 100 A ANL Windlass)Lewmar HX1 800 W EQ-061Shares SW-002 with House and Pilot; via contactor EQ-062 controlled by two foredeck switches; physical ANL rating/order untraced
DC-WIN-02Control fuse not verified; Lewmar manufacturer standard includes 3 A control fuseTwo foredeck switches SW-003 and SW-004 actuating contactor EQ-062 → HX1 EQ-061Separate low-current control function; fitted coil wiring, direction mapping and fuse position untraced

The 2025 Primary/Auxiliary/Watchkeeper/Winch ANL schedule must not be silently mapped to today’s six service circuit names. Unswitched does not mean unprotected. Assign individual FU-NNN records when particular fitted fuses and ways have been positively identified.

| DC-NAV-01 | CB-001 10 A, NAV LTS row 1 | EQ-021 — NASA Combi via SW-001 | Owner-confirmed 10 A and functional loads; DIN conductor paths not electrically traced | | DC-NAV-02 | CB-002 10 A, NAV LTS row 2 | EQ-020 — Osculati steaming function | Owner-confirmed 10 A and functional loads; DIN conductor paths not electrically traced | | DC-NAV-03 | CB-004 10 A, NAV LTS row 3 | EQ-020 — Osculati deck function, same physical housing | Owner-confirmed 10 A and functional loads; DIN conductor paths not electrically traced | | DC-NAV-04 | CB-005 10 A, NAV LTS row 4 | EQ-018 + EQ-019 — Osculati bow bicolour and stern LEDs | Owner-confirmed 10 A and functional loads; DIN conductor paths not electrically traced |

The NAV LTS panel contains four owner-confirmed 10 A branch breakers. The separate steaming and deck circuits feed different functions of the same Osculati fitting EQ-020; the bow and stern each have a luminaire but share CB-005. The exact DIN terminal assignments beyond legacy notes, conductor sizes and return paths remain unverified.

Communications power distribution

CB-003 protects the DC-COM-01 feeder. The 10 A / 3 A / 3 A branch fuses, allocated as FU-001–FU-003, protect their respective outgoing circuits. The 10 A VHF branch fuse equals the upstream 10 A breaker nominal rating; selectivity is not established without fuse/breaker characteristics. EQ-057’s fourth position is not confirmed as occupied or spare.

NMEA 2000 power injection

CircuitProtectionFunctional destinationEvidence / outstanding detail
DC-N2K-01CB-007 — one shared 10 A NAV INSTR breakerCommon supply to A and B injection feedsOwner-confirmed; split point and wiring untraced
DC-N2K-02Shared upstream CB-007; local fuse unknownSegment A power injection behind DCPOwner-confirmed functional feed; historical R1 alias untraced
DC-N2K-03Shared upstream CB-007; local fuse unknownSegment B power injection behind DCPOwner-confirmed functional feed; historical Y1 alias untraced

The A/B power isolator separates positive supplies at the network interconnection; it does not give these two feeds independent upstream breaker protection. Local protective devices and conductor suitability have not been surveyed.