Circuit Register
Status: owner-confirmed, not independently tested. Circuit identities are distinct from equipment and physical locations.
| Circuit | Primary protection | Destination | Survey status |
|---|---|---|---|
| DC-COM-01 | CB-003 10 A, panel 3,4 (VHF AIS) | EQ-057 four-way COM-frame fuse board | Owner-confirmed; feeder cable untested |
| DC-COM-02 | FU-001 10 A, EQ-057 way 1 | EQ-003 Icom M510 VHF | Owner-confirmed branch protection; conductor not surveyed |
| DC-COM-03 | FU-002 3 A, EQ-057 way 2 | EQ-005 Digital Yacht SPL2000 | Owner-confirmed branch protection; conductor not surveyed |
| DC-COM-04 | FU-003 3 A, EQ-057 way 3 | EQ-004 Ocean Signal ATB1 | Owner-confirmed branch protection; conductor not surveyed |
House-bank primary DC distribution
Source: The complete House bank remains one interface EQ-059. The owner confirms fitted battery-post MRBF fuses and ANL distribution fuses, with one common SW-002 for House, Autopilot and Windlass; Watchkeeper and both pumps bypass it. Windlass also retains a fitted 70 A breaker CB-006. Current ANL fuse ratings, positions and six-service mapping remain unverified. Distribution diagram.
| Circuit | Installed protective evidence | Functional destination | Switching / outstanding detail |
|---|---|---|---|
| DC-PWR-01 | Battery-post fuses owner-confirmed installed; 2025 design specified 2 × 125 A MRBF | EQ-059 → BB-003 | Current count, rating and cabling not inspected |
| DC-WAT-01 | ANL fuse installation confirmed as a group; particular fuse/rating not yet mapped | Watchkeeper | Unswitched by SW-002 |
| DC-BIL-01 | Pump circuit protection untraced | Pump 1 | Unswitched by SW-002 |
| DC-BIL-02 | Pump circuit protection untraced | Pump 2 | Unswitched by SW-002 |
| DC-HOU-01 | Original ANL installation owner-confirmed; fuse allocation not yet traced | Main DC panel EQ-001 | Shares SW-002 with Pilot and Windlass |
| DC-PIL-01 | Original ANL installation owner-confirmed; individual branch protection not yet mapped | Autopilot | Shares SW-002 with House and Windlass |
| DC-WIN-01 | CB-006 fitted 70 A breaker plus installed ANL scheme (2025 design called for 100 A ANL Windlass) | Lewmar HX1 800 W EQ-061 | Shares SW-002 with House and Pilot; via contactor EQ-062 controlled by two foredeck switches; physical ANL rating/order untraced |
| DC-WIN-02 | Control fuse not verified; Lewmar manufacturer standard includes 3 A control fuse | Two foredeck switches SW-003 and SW-004 actuating contactor EQ-062 → HX1 EQ-061 | Separate low-current control function; fitted coil wiring, direction mapping and fuse position untraced |
The 2025 Primary/Auxiliary/Watchkeeper/Winch ANL schedule must not be silently mapped to today’s six service circuit names. Unswitched does not mean unprotected. Assign individual FU-NNN records when particular fitted fuses and ways have been positively identified.
Navigation and deck lighting
| DC-NAV-01 | CB-001 10 A, NAV LTS row 1 | EQ-021 — NASA Combi via SW-001 | Owner-confirmed 10 A and functional loads; DIN conductor paths not electrically traced | | DC-NAV-02 | CB-002 10 A, NAV LTS row 2 | EQ-020 — Osculati steaming function | Owner-confirmed 10 A and functional loads; DIN conductor paths not electrically traced | | DC-NAV-03 | CB-004 10 A, NAV LTS row 3 | EQ-020 — Osculati deck function, same physical housing | Owner-confirmed 10 A and functional loads; DIN conductor paths not electrically traced | | DC-NAV-04 | CB-005 10 A, NAV LTS row 4 | EQ-018 + EQ-019 — Osculati bow bicolour and stern LEDs | Owner-confirmed 10 A and functional loads; DIN conductor paths not electrically traced |
The NAV LTS panel contains four owner-confirmed 10 A branch breakers. The separate steaming and deck circuits feed different functions of the same Osculati fitting EQ-020; the bow and stern each have a luminaire but share CB-005. The exact DIN terminal assignments beyond legacy notes, conductor sizes and return paths remain unverified.
Communications power distribution
CB-003 protects the DC-COM-01 feeder. The 10 A / 3 A / 3 A branch fuses, allocated as FU-001–FU-003, protect their respective outgoing circuits. The 10 A VHF branch fuse equals the upstream 10 A breaker nominal rating; selectivity is not established without fuse/breaker characteristics. EQ-057’s fourth position is not confirmed as occupied or spare.
NMEA 2000 power injection
| Circuit | Protection | Functional destination | Evidence / outstanding detail |
|---|---|---|---|
| DC-N2K-01 | CB-007 — one shared 10 A NAV INSTR breaker | Common supply to A and B injection feeds | Owner-confirmed; split point and wiring untraced |
| DC-N2K-02 | Shared upstream CB-007; local fuse unknown | Segment A power injection behind DCP | Owner-confirmed functional feed; historical R1 alias untraced |
| DC-N2K-03 | Shared upstream CB-007; local fuse unknown | Segment B power injection behind DCP | Owner-confirmed functional feed; historical Y1 alias untraced |
The A/B power isolator separates positive supplies at the network interconnection; it does not give these two feeds independent upstream breaker protection. Local protective devices and conductor suitability have not been surveyed.