DC-COM-02 — Icom M510 VHF power

← Circuit Register · COM-frame diagram · Fuse equipment

Owner-confirmed branch assignment and fuse rating. The physical conductor, terminations and return path have not been independently surveyed.

FieldValue
Circuit identifierDC-COM-02
SourceEQ-057 four-way fuse board on the COM frame
Primary branch protectionFU-001, 10 A, fuse position 1
LoadEQ-003 — Icom M510 VHF
Upstream feederDC-COM-01, protected by CB-003 10 A
Branch conductor/returnType, cross-section, length, termination and routing not yet confirmed
Evidence statusOwner-confirmed load, fuse way and ampere rating; wiring not independently traced

Protected circuit: This fuse protects the conductor from position 1 of EQ-057 to Icom M510 VHF. The upstream 10 A CB-003 feeder protection is separate.

Coordination note: The 10 A VHF branch fuse and upstream 10 A feeder breaker share a nominal current rating. This does not prove selectivity; confirm breaker and fuse time-current characteristics and the relevant cable sizes at refit.

Remaining survey

Identify the fuse format and its actual characteristics; inspect conductor gauge, polarity, route, termination and return path before declaring the installation independently verified.