DC-HOU-01 — House — remotely switched supply
← Circuit Register · House-bank supply diagram
Owner-reported circuit purpose; electrical installation not independently surveyed. Owner-confirmed House circuit, controlled together with Autopilot and Windlass by one common remote switch SW-002; feeder protection, cable size and actual switch output splitting untraced.
| Field | Record |
|---|---|
| Circuit | DC-HOU-01 |
| Source | BB-003 positive distribution |
| Function / destination | Main Moody chart-table DC panel EQ-001 and downstream house services |
| Functional control | SW-002 common remote switch; House, Autopilot and Windlass simultaneously ON/OFF, Watchkeeper and both pumps unaffected |
| Installed branch fuse / breaker | Original ANL fusing installed per owner, exact service allocation and value not independently verified |
| Source protection / isolation | Unknown; input connection to source and upstream protection not surveyed |
| Cable and return path | Conductor size, route, overcurrent coordination, negative return through the BMV-712 system-side shunt terminal unverified |
This circuit is a functional link, not evidence that a correctly rated protective device has been inspected. The service’s switching state, its fusing and its protective role are independent properties. The unswitched circuits remain live while the common SW-002 House/Autopilot/Windlass switch is OFF; do not interpret unswitched as unprotected.
Outstanding physical inspection
Identify the fitted circuit protective device and rating, branch/feeder conductor cross-section, its DC panel or load endpoint, correct negative return via the BMV-712 shunt, and the controlling hardware where relevant.