DC-NAV-04 — Osculati bow bicolour LED and stern LED
← Circuit Register · Navigation-light topology
Owner-confirmed circuit function, not independently traced or measured. Ragtime’s original Moody NAV LTS breaker panel contains four 10 A breakers. This branch is physically position 4, labelled NAVIGATION LIGHTS in the owner-supplied close-up. The 10 A rating comes from owner confirmation, not a visible breaker-body marking.
| Field | Record |
|---|---|
| Circuit ID | DC-NAV-04 |
| Source | EQ-002 NAV LTS panel, upper-left of EQ-001 main DC panel |
| Primary circuit protection | CB-005 10 A, panel position 4 |
| Load | EQ-018 and EQ-019 — Osculati bow bicolour LED and stern LED |
| Switching and wiring | Handwritten B3 → green Oceanflex 7 × 1.5 mm² trunk core for bow; B1 also stern-light-labelled (first abbreviation unclear). CB-005 protects both luminaires per owner, but full wiring routes, branch point and returns untraced. |
| Supply busbar, return path, cable size and length | Bow panel-to-forecabin branch uses Oceanflex 7 × 1.5 mm² owner-confirmed trunk; stern route may be separate and is unknown. Schedule |
| Provenance | Owner confirmation, 31 October 2026; any terminal references from earlier DC Logical Circuits notes |
Shared breaker: One 10 A breaker feeds both bow and stern luminaires. The branch point and individual return arrangement are unknown.
Second card’s conflicting allocation: The seven-core green conductor is written as STEAM + in the second handwritten card, but B3/green is written as NAV LTS (Bow) in the original panel schedule. The confirmed CB-005 → bow/stern protection relationship is unchanged; B3/green → bow must stay labelled as unverified historic panel notation until the forecabin starboard-locker connectors are traced. Source comparison.
Remaining survey
Confirm breaker maker/DC voltage rating, terminal numbering through the DIN clamp blocks, conductor ampacity/size, return routing, voltage drop and physical device labels. Do not infer a cable size or protection suitability from the stated breaker rating.