DC-PIL-01 — Autopilot — remotely switched supply
← Circuit Register · House-bank supply diagram
Owner-reported circuit purpose; electrical installation not independently surveyed. Owner-confirmed separate Autopilot supply circuit, but controlled together with House and Windlass by the one common remote switch SW-002. Breaker/fuse rating and downstream wiring unverified.
| Field | Record |
|---|---|
| Circuit | DC-PIL-01 |
| Source | BB-003 positive distribution |
| Function / destination | Autopilot distribution: NAC-3 and steering drive related equipment, protected subcircuits not yet allocated |
| Functional control | SW-002 common remote switch, simultaneously controlling Autopilot, House and Windlass; NOT independent remote isolation |
| Installed branch fuse / breaker | Original ANL fusing installed per owner, precise branch allocation and nominal value not independently verified |
| Source protection / isolation | Unknown; input connection to source and upstream protection not surveyed |
| Cable and return path | Conductor size, route, overcurrent coordination, negative return through the BMV-712 system-side shunt terminal unverified |
This circuit is a functional link, not evidence that a correctly rated protective device has been inspected. The service’s switching state, its fusing and its protective role are independent properties. The unswitched circuits remain live while the common SW-002 House/Autopilot/Windlass switch is OFF; do not interpret unswitched as unprotected.
Outstanding physical inspection
Identify the fitted circuit protective device and rating, branch/feeder conductor cross-section, its DC panel or load endpoint, correct negative return via the BMV-712 shunt, and the controlling hardware where relevant.
NMEA 2000 connection and separate operating power
Owner clarification, 6 November 2026: NAC-3 EQ-073 retains its separate autopilot operating-power feed; its connection to NMEA 2000 segment B is for network/data. This resolves the earlier blanket statement that all segment B devices were bus-powered. Detailed power wiring and protective-device allocation still require documentation.