Owner-confirmed circuit and protection facts: Windlass is on the same common SW-002 remote switch as House and Autopilot. A dedicated 70 A breaker CB-006 was retained in the windlass feed. The original ANL and battery-post fuses were also fitted, but the present physical fuse ratings and series connections have not been inspected.
| Property | Recorded value |
|---|---|
| Circuit ID | DC-WIN-01 |
| Source | House-bank distribution BB-003, via common SW-002 |
| Destination | EQ-061 Lewmar HX1 800 W, owner-confirmed installed; motor terminals and mechanical details not yet electrically surveyed |
| Contactor and controls | Separate windlass EQ-062 contactor controlled by two foredeck switches SW-003 and SW-004; control direction allocation, cable colours, supply and protective fuse untraced |
| Confirmed protective device | CB-006 70 A circuit breaker, retained and fitted |
| Additional protection | ANL fuse installation owner-confirmed; the 5 August 2025 design specifies 100 A ANL Windlass, not independently read from a fitted fuse |
| Original proposed cable | 25 mm², 10 m nominal windlass run in 2025 plan; actual fitted size/length unverified |
| Negative return | Must use system side of BMV-712 shunt if supplied by house bank; actual path untraced |
Evidence and protection coordination
The owner has now confirmed both the historical ANL/battery-post fuse installation and retention of the 70 A windlass breaker. Earlier July 2025 discussions cited the 70 A breaker for local isolation. The August 2025 article proposed a 100 A ANL windlass feed. There is no basis to treat the two devices as mutually exclusive.
Until checked aboard, do not claim their precise series order, fuse class/rating, conductor protection adequacy or selective tripping. Keep windlass on the one common remote-switched side, not a dedicated second switch.
Current owner-confirmed windlass configuration
1 November 2026: The installed windlass is specifically Lewmar HX1 800 W. The dedicated circuit breaker is 70 A. A separate contactor switches the windlass motor and is operated by two physical switches on the foredeck. The two switches are documented as individually identified controls, but which is UP and DOWN and whether any other control stations exist remain unverified. The earlier 80 A breaker reference was incorrect and is superseded by the owner’s 70 A confirmation.
The Lewmar HX1 manufacturer’s manual identifies a 70 A supplied breaker (68000240), contactor 68000939 and a 3 A control circuit fuse in its standard wiring scheme. These part numbers and control fuse are manufacturer references, not proof those exact accessory parts or fuse ratings are fitted aboard Ragtime. Windlass equipment · Contactor · Controls, SW-004.
Next inspection
Confirm windlass motor/controller; inspect the mounting and part markings of CB-006 at the aft end of the engine drive compartment beneath the aft cabin bunk; trace the relevant ANL fuse holder and markings, cable sizes, negative return and the switched-output branch point.