DC-WIN-02 — Windlass foredeck control circuit

← Circuit Register · Windlass power circuit · Windlass EQ-061

Owner-confirmed function, control supply untraced: Two separate switches mounted on the foredeck, SW-003 and SW-004, command contactor EQ-062, which operates the Lewmar HX1 800 W motor EQ-061. This is a low-current functional control relationship, separate from high-current motor supply DC-WIN-01.

AttributeCurrent documentation
Logical control circuitDC-WIN-02
Operator inputsTwo separate foredeck switches SW-003 and SW-004, exact UP/DOWN mapping not yet established
Controlled deviceEQ-062 windlass contactor
Controlled loadEQ-061 Lewmar HX1 800 W
Control source and returnUnknown; no traced fuse position, earth return, terminal number or wire colour
Installed control fuseUnknown; manufacturer standard circuit shows 3 A fuse, not established fitted
Installed control cableUnknown; Lewmar standard suggests 1.5 mm² switch wiring, not an as-fitted observation
Other control stationsNot established by owner evidence; do not assume absent

The shared SW-002 is the upstream high-current common battery-switching function, not one of the two foredeck contactor switches. The 70 A CB-006 protects the windlass motor supply, not a confirmed 70 A control circuit.

Reference: Lewmar HX1 installation and wiring manual, Issue 2, section 4.

Next inspection

Identify both foredeck positions, UP/DOWN operation, contactor coil/command terminal locations, control supply source and protective device, and any cabling to additional controls.