COM frame — DC and RF functional connections
Status: Owner-confirmed functional topology, not independently tested. CB-003 (10 A) feeds EQ-057. Fuse assignments are now way 1 = 10 A VHF, way 2 = 3 A SPL2000, way 3 = 3 A ATB1; way 4 remains unknown. The shared antenna uses continuous white Ancor RG213 with soldered PL-259 ends and no intermediate joints. DC conductor sizes and measured SWR remain outstanding.
← Electrical configuration · Equipment Register · Location reference system
Physical locations
SL-COM— COM frame: saloon, starboard-forward side, adjacent to the original main DC panel. Holds EQ-003 Icom M510, EQ-004 Ocean Signal ATB1, EQ-005 Digital Yacht SPL2000 and EQ-057 four-way FC fuse board.MS-T— masthead: EQ-058 shared VHF/AIS-band-compatible Vesper Marine VA159 antenna (manufacturer and model owner-confirmed).
DC distribution — owner-confirmed
Labels identify physical devices and independent circuit IDs. The feeder breaker and branch fuses have distinct protection responsibilities; fuse formats, wiring sizes and selective tripping are not yet verified.
The 10 A feeder breaker CB-003 protects DC-COM-01 to EQ-057, whereas the individual fuses FU-001–FU-003 protect the outgoing VHF, SPL2000 and AIS branch circuits. Branch fuse ratings and positions are owner-confirmed; actual conductor sizes, fuse types and selective tripping behaviour are not verified.
The fourth physical way on the FC fuse board has no confirmed assignment. It must not be described as spare until checked. See the Circuit Register for authoritative circuit-to-protection relationships.
RF signal paths — owner-confirmed functional topology
Connections are bidirectional for transmit/receive operation; this diagram shows topology, not signal direction. Cable type and connections are owner-confirmed, but actual SWR, insertion loss and end-connector condition have not been measured.
The owner confirms a white Ancor Marine Grade RG213 coax cable runs from the Vesper VA159 internally down the mast, passes through a swan-neck pipe into the deckhead, then continues to the SPL2000. The owner explicitly confirms it is one uninterrupted length with no intermediate coax connectors or splices, chosen to avoid additional connection losses. Estimated length is mast height + 3 m (owner estimate; exact length not measured). Both end connectors are soldered PL-259s, owner-confirmed; condition of the terminations and swan-neck sealing/strain relief remain unverified. No SWR readings are available. The owner confirms the VHF and AIS RF connections through the SPL2000 and the single masthead antenna. The SPL2000 manufacturer documents common-antenna operation, including a fail-safe VHF path in the event of lost splitter power. The optional AM/FM port is not documented as connected aboard Ragtime.
Manufacturer reference — Ancor white RG213
| Specification | Ancor catalogue value |
|---|---|
| Impedance | 50 Ω |
| Nominal outside diameter | 10.3 mm |
| Conductors / screening | Tinned copper centre and braid; 96% braid coverage |
| Sheath | UV-inhibited white PVC |
| Capacitance | 30.8 pF/ft |
| Propagation velocity | 66% |
| Attenuation | 1.9 dB/100 ft at 100 MHz, not a measured 162 MHz loss |
The cable is an RF transmission connection, not a new powered equipment asset. The run has no intermediate connectors, owner-confirmed; estimated length is mast height + 3 m, not physically measured. End-termination type: soldered PL-259 at both ends, owner-confirmed. Physical connector condition, environmental sealing and measured loss remain unverified; SWR has not been measured.
- Ancor 2024 manufacturer catalogue (PDF, coax specifications on printed page 16)
- Digital Yacht SPL2000 installation manual (PDF)
Operational RF observation
Following installation of the lower-attenuation RG213 cable, the owner observed a marked improvement in VHF reception, including reception of Jersey Coastguard from Weymouth Bay. This is a qualitative operational observation, not a quantified path-loss, radio-range or SWR measurement; environmental and installation factors also affect VHF reception.
Outstanding onboard survey
- CB-003 → EQ-057 and ways 1–3 are owner-confirmed; check feeder conductor sizing, fuse-board make/model and whether way 4 is occupied.
- The three ratings and way numbers are confirmed. Record actual fuse formats, conductor sizes/returns and time-current coordination during the panel refit.
- Ancor RG213, the inside-mast/swan-neck route, no intermediate joints, two soldered PL-259 end connectors and estimated length (mast height + 3 m) are owner-confirmed. Only actual length and connector condition/inspection remain open.
- No SWR readings are available. A future VHF/AIS-frequency VSWR test, end-connector inspection and swan-neck chafe/moisture check would provide further evidence.
- Recheck these supply and protection relationships when the main DC panel is replaced in the planned winter refit.