Electrical Reference System

Status: Proposed convention — not an as-built wiring record. Numerical identifiers and electrical relationships on this page are illustrative until confirmed by a survey aboard Ragtime. Do not use example connections or protective-device ratings as installation instructions.

The objective is to identify a circuit, find the breaker or fuse protecting it, and locate any switch, terminal or piece of equipment aboard Ragtime. The convention takes inspiration from Royal Navy location and equipment referencing, without introducing warship-scale complexity.

Four separate concepts

ConceptExampleMeaning
LocationCT-PThe physical location of an item
EquipmentCB-014A particular circuit breaker
CircuitDC-PIL-01A specific electrical circuit
RelationshipCB-014 protects DC-PIL-01How a device participates in a circuit

An equipment ID does not encode location, and a circuit ID does not encode its protective device. Consequently, equipment can move and protection can be replaced without renumbering the circuit.

Location codes

Start with recognisable compartments or functional areas, adding a sublocation only when precision matters.

CodeProposed location
FPForepeak / anchor locker
FCForward cabin
SLSaloon
CTChart table / navigation station
GLGalley
HDHeads
ACAft cabin
EREngine compartment
ALAft locker / steering compartment
CPCockpit
HMHelm / pedestal
MSMast
BLBilge

Examples: CT-P = chart table panel face; CT-R = rear of chart table panel; AL-S = starboard side of aft locker; MS-T = masthead. The generic examples remain proposed until surveyed.

Owner-designated sublocations

CodeNamePhysical descriptionEvidence and scope
SL-COMCOM frameSaloon, starboard-forward side, adjacent to the chart-table DC panelOwner-designated location (31 October 2026). Includes Icom M510 (EQ-003), Ocean Signal ATB1 (EQ-004), Digital Yacht SPL2000 (EQ-005), and four-way FC fuse board (EQ-057). Supply and RF paths owner-reported; conductor and fuse ratings not surveyed.
MS-TMastheadMasthead antenna/light mounting areaOwner confirms the Vesper Marine VA159 VHF/AIS-band antenna (EQ-058) connected to the SPL2000 on the COM frame; coax details and measured VSWR pending.

The COM frame is a location, not an equipment item or circuit. Its location code is deliberately independent of the equipment IDs, so devices can be replaced or relocated without renumbering them.

Equipment record and index status

Equipment documentation progress and electrical verification are distinct. Each equipment page owns its survey_state (for example U, T or G) and optional documentation_stage. The Equipment Register and Catalogue use a Hugo equipment-status shortcode to render these values automatically; do not separately maintain status in their tables.

  • documentation_stage: mapped — equipment identity, location and relevant functional connections have been documented from owner information. This is not independently verified as-built electrical work.
  • survey_state: U — installation not independently electrically surveyed, even if the owner has confirmed details; T = tentative, G = grouped.
  • A completed physical inspection or electrical test should be recorded with its evidence and only then change the applicable survey state.

Equipment references

Assign permanent identifiers to significant components, unique within the equipment type.

PrefixType
SWSwitch or control
CBCircuit breaker
FUFuse
TBTerminal block
BBBusbar
RLRelay or contactor
BATBattery
EQOther electrical equipment

Thus CB-014 denotes a breaker regardless of its panel position. Its equipment record should contain its physical location, make, model, rating and a photograph. Keep installation and change history separate from the identifier.

Circuit references

Use <SUPPLY>-<SYSTEM>-<NUMBER>, with examples such as DC-PWR-01 for DC power distribution, DC-PIL-01 for autopilot power and AC-PWR-01 for an AC distribution circuit. The system abbreviation describes the function; the number does not correspond to a breaker or switch number.

Examples here remain illustrative; the first real circuit is DC-COM-01, protected by CB-003 and supplying EQ-057.

Relationship between a breaker and a circuit

Model protection as an explicit circuit-to-device relationship. The circuit record should identify its source, primary branch protection, upstream protection and loads. Crucially, a breaker or fuse protects a defined downstream conductor or wiring section, not necessarily a complete functional subsystem.

RelationshipIllustrative example
SupplyDC-PIL-01 supplied from BB-001
Primary branch protectionCB-014 protects DC-PIL-01
Upstream protectionFU-001 upstream of CB-014
LoadDC-PIL-01 feeds EQ-019
LocationCB-014 located at CT-P

The Circuit Register is authoritative for the protective relationship. A breaker’s equipment page can display the reverse relationship — circuits protected by this device — rather than keeping a second copy that might become inconsistent.

A proposed future structured circuit record:

id: DC-PIL-01
name: Autopilot power
status: proposed
source: BB-001
protection:
  primary: CB-014
  upstream:
    - FU-001
loads:
  - EQ-019

This YAML is only an example, not an as-installed circuit. Each protective device’s position in the actual wiring, size, rating and conductor cross-section must be verified.

Preserve existing physical markings

The current DC Logical Circuits page describes breaker positions by column and row (such as 1,1), individual cage-clamp connector positions (such as B2 and Y3), and existing busbar names (DC-BB-M and DC-BB-A).

Confirmed DIN connector reference convention

Behind the main DC panel are separate generic cage-clamp connectors, arranged by the owner into repeating groups of Yellow → Red → Blue lever colours. Groups are numbered from the top down following the legacy notes. The code combines connector lever colour + group number, not cable insulation colour or an equipment ID.

Physical aliasExact meaning
Y1Yellow lever connector, group 1
R1Red lever connector, group 1
B1Blue lever connector, group 1
Y2Yellow lever connector, group 2 — legacy steaming-light connection
B2Blue lever connector, group 2 — legacy masthead connection
Y3Yellow lever connector, group 3 — black-insulated trunk core; legacy NASA masthead assignment superseded; −12 V busbar connection currently an assumption
R3Red lever connector, group 3 — brown trunk core; owner-confirmed NASA Combi switched leg through SW-001
B4Blue lever connector, group 4 — white trunk core; owner-confirmed second NASA Combi switched leg through SW-001
R4Red lever connector, group 4 — radar + in legacy handwritten schedule; circuit not verified

A group is a physical ordering convention, not one electrically common three-terminal block. TB-001 and TB-002 currently document the second and third groups, respectively, without inventing equipment IDs for every clamp or claiming cross-connections. The photo supplied is incomplete; total group count, populated terminals, jumpers, actual wiring and equipment manufacturer’s identity remain to be surveyed.

Do not conflate (1) cage-clamp lever colour, (2) panel-to-forecabin trunk core colour, or (3) manufacturer pigtail lead colour. They may differ: Y3 is a yellow-lever clamp connected to the black core of an Oceanflex 7 × 1.5 mm² trunk to the forecabin locker. The owner-confirmed NASA Combi switched pair is R3/brown and B4/white, continuing into its separate Oceanflex 2 × 1.5 mm² mast cable; earlier B2/blue and Y3/black NASA annotations are superseded. Neither NASA wire is permanently negative. The seven-core black and separate three-core steaming/deck black busbar links remain a hypothesis, not measurements. See the transcribed handwritten terminal schedule.

Keep these as physical position references and legacy aliases while migrating to the new conventions. Do not silently replace verified onboard markings with newly invented numbers.

Verified versus proposed

Every future register entry should distinguish Installed / Verified, Installed / Unverified, Planned and Retired. Record the last physical verification date, location, connection and terminal references, protective-device ratings, cable details and photographs where practicable.

The sensible first survey is the chart-table DC panel. From that we can progressively build the Location Register, Equipment Register and Circuit Register without inventing wiring that has not yet been traced.