BB-003 — House-bank positive distribution

← Equipment Register · House DC distribution

Owner-confirmed: Main positive distribution with three unswitched services and a single common remotely switched supply feeding three other services. Original ANL and battery-post fuses were fitted; device ratings and exact way allocation have not been independently inspected.

Functional supply relationships

Supply / outputConnection evidence
SourceAggregated house-bank positive port EQ-059; battery-post fuses installed, exact positions/ratings not surveyed
WatchkeeperDC-WAT-01 — bypasses common SW-002
Pump 1DC-BIL-01 — bypasses SW-002
Pump 2DC-BIL-02 — bypasses SW-002
Shared switched feedOne SW-002 remote battery switch; not three switches
HouseDC-HOU-01 — downstream of SW-002
AutopilotDC-PIL-01 — downstream of same SW-002
WindlassDC-WIN-01 → Lewmar HX1 EQ-061 via separate contactor EQ-062; controlled by two foredeck switches; retains fitted 70 A CB-006

Physical modular assembly and fusing

The owner-supplied 5 August 2025 photograph shows one WhisperPower-branded Remote Battery Switch, four obvious lower transparent-covered high-current fuseholders and additional covered busbar/terminal positions. These are historical photographs of installed-style hardware, not readable fuse ratings or individually assigned branches.

Owner update: All the original ANL fuses and battery-post fuses were fitted, alongside retention of the Windlass 70 A breaker. The 5 August 2025 article lists ANL nominal ratings 80 A Primary / 80 A Auxiliary / 100 A Windlass / 40 A Watchkeeper. The earlier July source design lists two 125 A MRBFs. These historical values are not currently labelled as individually verified as fitted, and the old Primary/Auxiliary names must not be silently substituted for current House/Autopilot circuit IDs.

The six owner-confirmed functional services do not establish six physical busbar studs or six fuseholders. Record actual fuse element markings, studs/jumpers, remote switch input/output, cable ratings and connected circuits at next access. See source topology.

Record maintenance

  • 31 October 2026: Owner confirms six functional outputs, one common switch for House/Autopilot/Windlass, fitted ANL and battery-post fuses, and retained 70 A windlass breaker. No continuity/ratings verification conducted.