CB-003 — VHF AIS DC panel circuit breaker, 10 A

← Equipment Register · Main DC panel · COM-frame supply

Status: owner-confirmed 10 A feeder; cable still untested. This breaker, at CT-P 3,4 and labelled VHF AIS, feeds the four-way COM fuse board via DC-COM-01.

Identity and physical position

FieldRecorded valueBasis
Permanent equipment IDCB-003Register allocation
DescriptionMain DC panel “VHF AIS” circuit breakerFaceplate close-up
LocationCT-P — main DC panel, chart tableOwner-confirmed panel location
Physical positionColumn 3, row 4 (3,4), lower right of 12-position bankOwner-confirmed; matches photograph
Faceplate inscriptionVHF AISReadable in owner-supplied close-up
Owner’s description“VHF”Owner’s abbreviated identification
Nominal current rating10 AOwner-confirmed; rating not legible on face photograph
Manufacturer / breaker type / trip characteristicNot identifiedAwait rear/side label
StatusExisting fitted breaker; scheduled panel replacement winter 2026–27Owner-reported refit intent
Last evidence31 October 2026 — owner close-up and stated ratingFront photograph, not internal inspection

Protection and connected equipment

Owner-confirmed: CB-003 protects feeder DC-COM-01 from the original main DC panel to EQ-057 on the COM frame.

EQ-001 main DC panel
  | CB-003, 10 A, 3,4, VHF AIS
  | DC-COM-01 (confirmed feeder)
  v
EQ-057 four-way COM fuse board
  |-- unknown fuse --> EQ-003 Icom M510 VHF
  |-- unknown fuse --> EQ-004 ATB1 AIS
  '-- unknown fuse --> EQ-005 SPL2000

The 10 A rating applies to the feeder breaker, not the individual downstream branch fuses. Feeder conductor type/size, polarity of terminals, DC breaking capacity, return path and actual continuity testing remain unverified.

Photographic reference

A clear owner-supplied close-up of the original Moody 336 panel shows the lower-right breaker and “VHF AIS” legend. The 10 A rating is not visually readable in that photo; it is recorded from the owner’s statement.

See the main panel photographic record for the broader assembly. The close-up supplied on 31 October 2026 should be archived alongside this record when the photo repository workflow is established.

Product documentation

Manufacturer and breaker series are not yet identified. A trustworthy breaker datasheet or PDF manual cannot be assigned without the marking on the device body. The period Moody 336 owner’s manual (PDF) documents the original vessel electrical architecture but does not establish this specific breaker model or rating.

Outstanding checks

  1. The owner confirms this feeder. Trace or test the conductor when the panel is accessible.
  2. Photograph the actual breaker side/rear markings to establish manufacturer, rated voltage, breaking capacity, trip characteristics and 10 A marking.
  3. Record the outgoing feeder conductor size, length, return path and upstream protection.
  4. Revisit and document the feeder/protection arrangement when the original Moody DC panel is replaced during the winter refit.

Record maintenance

  • Evidence: owner’s breaker position and 10 A declaration, plus supplied close-up showing the VHF AIS faceplate legend, 31 October 2026.
  • Owner-confirmed CB-003 → EQ-057 connection, 31 October 2026. Electrical continuity, cable and breaker characteristics remain untested.