CB-006 — Windlass 70 A circuit breaker
← Equipment Register · Windlass circuit · House distribution
Owner-confirmed as fitted: The original windlass circuit breaker was retained, and its correct installed rating is 70 A as confirmed by the owner on 1 November 2026, in addition to the ANL fuses installed in the house-bank distribution. This confirms the breaker’s presence and nominal current, not its make, characteristic, continuity, condition or position relative to the ANL fuse.
| Attribute | Recorded value |
|---|---|
| Device | CB-006 — Windlass feeder circuit breaker |
| Nominal current | 70 A, owner-confirmed fitted |
| Protected circuit | DC-WIN-01 |
| Switching upstream | Common SW-002 for House, Autopilot and Windlass |
| Other source protection | ANL fuse(s) fitted, owner-confirmed; historic windlass ANL was specified 100 A, but actual value/physical order not yet inspected |
| Manufacturer/model/voltage/trip curve | Unknown |
| Physical location | Aft end of the engine drive compartment, beneath the aft cabin bunk — owner-confirmed 2 November 2026; mounting details not independently inspected |
| Cable sizes, series placement and selective coordination | Not measured or traced |
Do not conflate protections: The earlier 100 A ANL proposal and fitted 70 A breaker are distinct devices that can coexist in one feed; identifying a device’s presence does not establish its source-to-load order or trip selectivity.
Correction and manufacturer cross-check
1 November 2026 owner correction: The fitted breaker is 70 A, not 80 A. Earlier audit records carried forward an incorrect 80 A statement; this is superseded. Lewmar’s HX1 800 W manual specifies 70 A for the supplied breaker (manufacturer part 68000240); the installed breaker’s exact part number is unverified, and its trip characteristic and electrical placement relative to the ANL fuse still need inspection.
Windlass EQ-061 · Contactor EQ-062 · Foredeck switches SW-003 / SW-004.
Survey needed
Inspect the breaker mounting beneath the aft cabin bunk and read its face/body and DC rating; trace its incoming/outgoing lugs, windlass controller and the relevant installed ANL fuse; record the circuit’s actual positive/negative cable route and conductor sizes.