CB-007 — NAV INSTR shared 10 A breaker

← Equipment Register · NMEA 2000 network

Owner-confirmed, 6 November 2026: One 10 A NAV INSTR breaker feeds both NMEA 2000 segment A and segment B power injection points behind DCP.

FieldRecord
Equipment IDCB-007
Parent panelEQ-001 — main DC panel
Owner / historical labelNAV INSTR
Nominal rating10 A — owner-confirmed, not independently inspected
Panel coordinate / manufacturer / typeNot yet reported
Common protected supplyDC-N2K-01
DestinationsDC-N2K-02 — A injection and DC-N2K-03 — B injection, both behind DCP
Local branch fuses / switchesNot yet established
Conductors / split point / returnUntraced; sizes and suitability not independently checked

The two injection feeds share this physical breaker. The separate A/B network power isolator is not another breaker. Historical R1/A and Y1/B connector aliases remain untraced. Record additional local protection only when identified; no protective adequacy is inferred from the nominal breaker rating.