EQ-002 — NAV LTS breaker and yacht-graphic panel

← Equipment Register · Browse equipment

Status: owner-confirmed and photographed; not electrically inspected. The upper-left NAV LTS section of the original Moody panel includes four 10 A breakers (owner-reported rating), identified by their engraved labels and functions. The illuminated yacht graphic is visible, but its internal indicator circuits have not been traced. NAV lights diagram.

Identity and location

FieldValue
Permanent equipment IDEQ-002
EquipmentOriginal Moody NAV LTS four-breaker / yacht-graphic panel
Register categoryDC distribution and controls
Equipment classEQ
Reported locationDCP
Inventory stateFront photographed, 4 × 10 A breaker functions confirmed by owner; internal wiring not tested
Manufacturer / modelNot identified; owner survey required
Serial / part numberNot recorded
Last onboard verification31 October 2026 — front photograph; no electrical testing

Original reference and notes: NAV LTS upper-left faceplate section; whether mechanically separate from main panel is not verified.

Four owner-confirmed breaker functions

Position, top downFaceplate label (photographed)BreakerCircuitLoads
1MAST HEAD LIGHTCB-001, 10 ADC-NAV-01EQ-021 NASA Combi, through SW-001
2STEAMING LIGHTCB-002, 10 ADC-NAV-02EQ-020 steaming function
3DECK LIGHTSCB-004, 10 ADC-NAV-03EQ-020 deck function of same fitting
4NAVIGATION LIGHTSCB-005, 10 ADC-NAV-04EQ-018 bow bicolour and EQ-019 stern

DIN colour-clamp interconnection method and original mast cable colours are owner-confirmed; terminal assignments beyond legacy notes are not independently traced.

Electrical installation — as fitted

FieldSurveyed value
Supply voltage / inputNot measured or recorded
Source / distribution busbarNot established
Circuit identifierNot allocated; do not confuse this equipment ID with a circuit ID
Primary branch protective deviceNot confirmed
Upstream protective deviceNot confirmed
Cable / terminal referencesSee source notes and connections below; unverified until traced
Cable size, fuse/breaker rating and measured loadNot recorded

Important: a device’s manufacturer-rated input, current or recommended fuse is not proof of the actual cable, protection or wiring aboard Ragtime.

Known or reported relationships

  • EQ-001 — original Moody 336 parent panel, owner-confirmed. The upper-left yacht-outline section is visible in the panel photograph; serviceable-unit status unconfirmed.

Manufacturer reference

Original Moody 336 parent panel identified by the owner. No separate model/part number or electrical specification for this indicator section has been verified.

Documentation: No model-specific PDF manual linked yet.

Information requested from the owner

  1. Confirm whether the NAV LTS panel is mechanically serviceable as a distinct assembly and how the yacht-outline indicators are wired.
  2. Check the four breakers’ markings, DC breaking capacities, terminal positions and return distribution when the panel is opened.

Record maintenance

  • Evidence basis: existing website inventory, plus explicitly identified manufacturer references where applicable.
  • Verification: pending physical survey; photograph, nameplate data and protective-device references to be recorded.
  • Avoid publishing passwords, SIM identifiers, access tokens or other confidential credentials on this public site.