EQ-003 — Icom IC-M510 VHF transceiver
← Equipment Register · Browse equipment
Survey status: Owner-confirmed installed and located; wiring not verified. The owner identifies this equipment on the COM frame (
SL-COM) in the starboard-forward saloon beside the DC panel. Installation specifics (wiring, protection, interconnections) are not independently surveyed; manufacturer figures below are reference data, not measurements.
Identity and location
| Field | Value |
|---|---|
| Permanent equipment ID | EQ-003 |
| Equipment | Icom IC-M510 VHF transceiver |
| Register category | Communications |
| Equipment class | EQ |
| Reported location | SL-COM — COM frame, saloon, starboard-forward side adjacent to the DC panel (owner-confirmed) |
| Inventory state | Owner-confirmed installed; location known; electrical configuration unverified |
| Manufacturer / model | Icom M510 (owner-confirmed); exact regional/version suffix not yet recorded |
| Serial / part number | Not recorded |
| Last onboard verification | Owner-reported location, 31 October 2026; physical electrical survey outstanding |
Original reference and notes: Earlier circuit inventory said “Tranciever”; owner confirms an installed Icom M510 at the COM frame.
Electrical installation — as fitted
| Field | Surveyed value |
|---|---|
| Supply voltage / input | Not measured or recorded |
| Source / distribution busbar | EQ-001 main DC panel → EQ-057 four-way fuse board (owner-confirmed functional path; upstream CB-003 10 A owner-confirmed) |
| Supply branch circuit | DC-COM-02 — feeds this equipment, distinct from equipment ID |
| Primary branch protective device | FU-001 10 A, EQ-057 way 1, protecting DC-COM-02 — owner-confirmed rating/position; fuse format and conductor size unverified |
| Upstream protective device | 10 A CB-003 via DC-COM-01 to EQ-057, owner-confirmed; separate branch fuse unrecorded |
| Cable / terminal references | See source notes and connections below; unverified until traced |
| Cable size, fuse/breaker rating and measured load | Not recorded |
Important: a device’s manufacturer-rated input, current or recommended fuse is not proof of the actual cable, protection or wiring aboard Ragtime.
NMEA 2000 connection
Owner-confirmed, 6 November 2026: Connected to segment A for data only. The equipment’s operating power remains on its separate COM-frame DC circuit. See the segment A connection and power table. Network interface/adapter hardware, drop route and pin-level connections remain to be documented; no direct connector or interface model is inferred.
Known or reported relationships
EQ-057— owner-confirmed VHF output way 1, 10 A FU-001, circuit DC-COM-02.EQ-005— owner-confirmed SPL2000 VHF radio RF port connection.EQ-058— shared masthead VHF/AIS antenna reached through the splitter (not a direct antenna coax from VHF).EQ-004— ATB1 shares the antenna through the splitter; both devices have owner-confirmed data-only connections to NMEA 2000 segment A, with interface wiring untraced.
See the COM-frame functional supply and RF paths.
Manufacturer reference
Identification confidence: Manufacturer and M510 model family confirmed by owner; exact variant and nameplate data pending.
- Manufacturer: Icom; fixed-mount Class D DSC marine VHF.
- Manufacturer specifications for IC-M510 list 13.8 V DC nominal (11.7–15.9 V), 25 W / 1 W RF transmit power and approximately 5.5 A current at 25 W transmission (variant dependent).
- Check the exact IC-M510 / IC-M510E / EVO version before using any fuse or power specifications for the installed device.
Documentation
Information requested from the owner
- Which exact M510 variant is fitted (e.g. M510E), and what does its nameplate say?
- VHF branch is confirmed on way 1 (FU-001, 10 A). Check fuse format/curve and branch conductor size; CB-003 (also 10 A) may not selectively coordinate.
- Can you provide a rear/nameplate photo and confirm the VHF-to-SPL2000 coax connector and cable condition?
Record maintenance
- Evidence basis: existing website inventory and owner confirmation of COM-frame location on 31 October 2026; manufacturer documentation where model identifiable.
- Verification: installed position, fused-board supply and RF-to-splitter path owner-reported; circuit labels, individual fuse ratings, nameplate and coax details await survey.
- Avoid publishing passwords, SIM identifiers, access tokens or other confidential credentials on this public site.