EQ-036 — RUTX50 router

← Equipment Register · Browse equipment

Survey status: Listed, not physically verified. This record originates from the older DC Logical Circuits notes. It is not a verified-as-built electrical drawing. Model specifications are manufacturer reference information, not measured onboard data.

Identity and location

FieldValue
Permanent equipment IDEQ-036
EquipmentRUTX50 router
Register categoryLocal area network
Equipment classEQ
Reported locationUnsurveyed
Inventory stateListed, not physically verified
Manufacturer / modelTeltonika Networks RUTX50 5G industrial router
Serial / part numberNot recorded
Last onboard verificationNot recorded

Original reference and notes: Source: RUTX50; no other identifying particulars assumed.

Electrical installation — as fitted

FieldSurveyed value
Supply voltage / inputNot measured or recorded
Source / distribution busbarNot established
Circuit identifierNot allocated; do not confuse this equipment ID with a circuit ID
Primary branch protective deviceNot confirmed
Upstream protective deviceNot confirmed
Cable / terminal referencesSee source notes and connections below; unverified until traced
Cable size, fuse/breaker rating and measured loadNot recorded

Important: a device’s manufacturer-rated input, current or recommended fuse is not proof of the actual cable, protection or wiring aboard Ragtime.

Known or reported relationships

No other equipment-level relationships have yet been established in the register.

Manufacturer reference

Identification confidence: Model explicitly recorded on the source page; no serial or installed-wiring verification.

  • Manufacturer input: 9–50 V DC through a 4-pin industrial power connector.
  • Manufacturer lists idle consumption below 4 W and maximum consumption below 16.5 W; its measured power-consumption table varies with supply voltage and activity.
  • Manufacturer supports passive power over LAN1 (9–50 V, Mode B), not standards-compliant IEEE 802.3af/at/bt PoE. Check what powers Ragtime’s unit.
  • 5 gigabit Ethernet interfaces and dual SIM capability are model-level features, not proof that both SIMs are configured.

Documentation

Information requested from the owner

  1. Is this item currently installed, removed or planned? When was it last physically checked?
  2. What are its manufacturer, model/part number and serial number (if recorded)? Please provide a nameplate photograph.
  3. Where exactly is it mounted? A photo with surroundings would help.
  4. Which supply circuit, branch fuse/breaker and any upstream protective device feed it, and what are their actual ratings?
  5. Is the RUTX50 wired to its four-pin connector or passive PoE? What power supply and protective device are used?

Record maintenance

  • Evidence basis: existing website inventory, plus explicitly identified manufacturer references where applicable.
  • Verification: pending physical survey; photograph, nameplate data and protective-device references to be recorded.
  • Avoid publishing passwords, SIM identifiers, access tokens or other confidential credentials on this public site.