EQ-057 — COM-frame four-way FC fuse board
← Equipment Register · COM-frame overview
Status: Owner-confirmed installed fuse board and branch ratings; conductor protection not independently inspected. EQ-057 is fed from the original Moody DC panel through 10 A CB-003. Owner confirms way 1 = 10 A VHF, way 2 = 3 A SPL2000, way 3 = 3 A ATB1. The purpose of way 4 and the physical fuse formats remain unknown.
Identity and location
| Field | Value |
|---|---|
| Equipment ID | EQ-057 |
| Function | Four-way fused DC branch distribution for communications equipment |
| Owner’s label | “4 way FC fuse board” (FC expansion/manufacturer unverified) |
| Make/model and serial | Not recorded |
| Location code | SL-COM — COM frame, starboard-forward saloon adjacent to DC panel |
| State | Owner-confirmed installed; electrical details unverified |
| Verification evidence | Owner description, 31 October 2026; photo/nameplate not supplied |
Supply, protection and loads
| Item | Owner-reported relationship | Survey status |
|---|---|---|
| Feeder | DC-COM-01 from CB-003, 10 A, 3,4, VHF AIS | Owner-confirmed; conductor and return path not inspected |
| Way 1 | FU-001 — 10 A, protects DC-COM-02 to EQ-003 Icom M510 VHF | Owner-confirmed position and rating; fuse type / conductor unknown |
| Way 2 | FU-002 — 3 A, protects DC-COM-03 to EQ-005 Digital Yacht SPL2000 | Owner-confirmed position and rating; fuse type / conductor unknown |
| Way 3 | FU-003 — 3 A, protects DC-COM-04 to EQ-004 Ocean Signal ATB1 AIS | Owner-confirmed position and rating; fuse type / conductor unknown |
| Fourth way | Unknown (may be spare or another load) | Not confirmed |
Equipment allocation: EQ-057 identifies the four-way assembly; FU-001, FU-002 and FU-003 identify its three confirmed installed fuses. They protect DC-COM-02, DC-COM-03 and DC-COM-04 respectively. The fourth physical way remains unidentified; do not allocate a fourth FU equipment ID until its occupancy is established.
Electrical reference
- Nominal onboard DC distribution; the feeder breaker is 10 A and the branch fuses are 10 A, 3 A and 3 A, all owner-confirmed. Board manufacturer/rating, fuse formats and actual conductor protection remain unverified. Way 1 and upstream CB-003 both have nominal 10 A ratings; selective operation must not be assumed.
- Do not infer conductor protection from the manufacturer ratings of the three connected loads.
- The main panel is planned for replacement during the winter 2026–27 refit; the feeder/protection interface should be revisited as part of that work.
- COM-frame functional DC and RF topology (includes the linked distribution diagram).
- Circuit Register gives the circuit and protection mapping.
Manual: No model-specific PDF manual identified until the fuse board manufacturer and model are confirmed.
Information requested from the owner
- What does the board’s label say? A photo of the fuse carrier and rear wiring would establish the FC manufacturer/model.
- Ways and nominal ratings are now identified; photograph the fitted fuse types/manufacturers and conductors when convenient.
- Is way four spare or feeding another load?
- CB-003 supplies this board, owner-confirmed. Trace and record the feeder/return conductor sizes, terminals and routing.
Record maintenance
- Source: owner’s COM-frame description, 31 October 2026.
- Feeder CB-003 and branch ways/rating assignments 1: VHF 10 A; 2: SPL2000 3 A; 3: ATB1 3 A owner-confirmed, 31 October 2026. Fuse format, physical conductors and branch protection coordination remain to survey.