EQ-060 — Victron BMV-712 battery monitor and shunt
← Equipment Register · House distribution topology
Owner-confirmed functional topology, not a physical electrical test. Owner confirms fitted Victron BMV-712 monitoring the house bank. The shunt is directly connected to battery negatives through the bespoke tinned-copper BB-004 link.
Identity and functional boundary
| Field | Documentation |
|---|---|
| Equipment reference | EQ-060 |
| Classification | Equipment |
| Location | Shunt at battery negative terminals; monitor display location not yet recorded |
| Source evidence | Owner’s 31 October 2026 description, previous engineering design records and relevant earlier source material |
| Survey verification | No full current/continuity, physical switch/device label or installation measurements recorded |
Connections and interfaces
| Relationship | Documented status |
|---|---|
| Battery side of shunt | DIY tinned-copper negative bar BB-004 connected to house-bank negative terminals |
| System/load side of shunt | Common return for house services, pumps, autopilot, charging equipment and the main negative distribution, nominally BB-001; actual onward connection to BB-001 not yet physically traced |
| BMV sensing/power | Fused positive sense/power lead should remain available independently of remotely switched House/Autopilot outputs; actual feed termination and fuse are not documented |
Engineering and evidence notes
The shunt measures net battery current only when all house-bank load and charging returns pass through the load/system side. Battery negative is the sole connection class allowed on its battery side; do not add a return bypass. The BMV-712 model is owner-confirmed; actual shunt rated current not read from fitted label.
Keep distinct: House-bank internal composition and planned LiFePO4 replacement are outside this source-interface record. No proposed product, fuse size, cable gauge, or switching capacity should be labelled installed without independent evidence.
Outstanding survey
Photograph the fitted terminals and physical labels, identify any battery-side main protection, remote switch make/models and control/feed arrangements, conductor sizes, fuse identities, and the battery-shunt-system negative path. Identify actual source-to-panel termination and any manual disconnect procedure.