Owner-confirmed functional topology, not a physical electrical test. Owner confirms fitted Victron BMV-712 monitoring the house bank. The shunt is directly connected to battery negatives through the bespoke tinned-copper BB-004 link.

Identity and functional boundary

FieldDocumentation
Equipment referenceEQ-060
ClassificationEquipment
LocationShunt at battery negative terminals; monitor display location not yet recorded
Source evidenceOwner’s 31 October 2026 description, previous engineering design records and relevant earlier source material
Survey verificationNo full current/continuity, physical switch/device label or installation measurements recorded

Connections and interfaces

RelationshipDocumented status
Battery side of shuntDIY tinned-copper negative bar BB-004 connected to house-bank negative terminals
System/load side of shuntCommon return for house services, pumps, autopilot, charging equipment and the main negative distribution, nominally BB-001; actual onward connection to BB-001 not yet physically traced
BMV sensing/powerFused positive sense/power lead should remain available independently of remotely switched House/Autopilot outputs; actual feed termination and fuse are not documented

Engineering and evidence notes

The shunt measures net battery current only when all house-bank load and charging returns pass through the load/system side. Battery negative is the sole connection class allowed on its battery side; do not add a return bypass. The BMV-712 model is owner-confirmed; actual shunt rated current not read from fitted label.

Keep distinct: House-bank internal composition and planned LiFePO4 replacement are outside this source-interface record. No proposed product, fuse size, cable gauge, or switching capacity should be labelled installed without independent evidence.

Outstanding survey

Photograph the fitted terminals and physical labels, identify any battery-side main protection, remote switch make/models and control/feed arrangements, conductor sizes, fuse identities, and the battery-shunt-system negative path. Identify actual source-to-panel termination and any manual disconnect procedure.