EQ-062 — Windlass contactor

← Equipment Register · Windlass equipment EQ-061 · Power circuit · Control circuit

Owner confirms one separate installed contactor for the Lewmar HX1 800 W. Two individual foredeck switches control this contactor. The installed contactor’s manufacturer/model, rated current, coil voltage, terminal scheme and physical mounting location remain unidentified.

Control and power relationships

ConnectionEvidence
EquipmentEQ-062 — separate windlass contactor
Load/power outputTo the Lewmar HX1 800 W, EQ-061 motor; as-wired motor terminals and polarity not continuity-tested
Power feedDC-WIN-01 through common house/windlass remote switch SW-002 and fitted 70 A breaker CB-006; exact contactor/fuse sequence not traced
Control input 1SW-003, foredeck switch A; actual terminal and UP/DOWN function unconfirmed
Control input 2SW-004, foredeck switch B; actual terminal and UP/DOWN function unconfirmed
Control-path recordDC-WIN-02; actual supply source and control fuse still unknown
Fitted manufacturer/modelUnknown; do not infer it is Lewmar part 68000939 solely from the HX1 manual
Physical positionNot yet documented by photo/measurement

Manufacturer wiring reference

The Lewmar HX1 manual, Issue 2 shows a manufacturer-supplied contactor, part 68000939, with UP/DOWN switching and a 3 A control fuse in the standard circuit. This is a useful model to verify against Ragtime’s installation, not confirmation of the installed contactor part, fuse rating, foredeck control hardware or coil arrangement.

Outstanding survey

Photograph contactor markings and terminals; identify battery/power contacts, motor contacts and control inputs; trace the two foredeck control wires, control protection, switch directions and any alternative control stations.