FU-001 — COM-frame fuse way 1, 10 A, Icom M510 VHF

← Equipment Register · COM fuse board · Circuit Register

Owner-confirmed installed fuse position, rating and protected equipment. Physical fuse format, make, condition and conductor size have not been independently surveyed.

FieldConfirmed record
Permanent fuse IDFU-001
Physical assemblyEQ-057 four-way fuse board
LocationSL-COM — COM frame
Physical position / way1 (owner numbering)
Installed fuse rating10 A (owner-confirmed)
Protected branch circuitDC-COM-02
LoadEQ-003 — Icom M510 VHF
Upstream protectionCB-003 10 A, through feeder DC-COM-01
Fuse type, time-current curve and manufacturerNot recorded
Branch cable cross-section, length and returnNot recorded

Protection distinction: FU-001 protects the DC-COM-02 branch conductor; CB-003 protects the upstream DC-COM-01 feeder. Coordination/discrimination and cable adequacy have not yet been assessed.

Review at winter refit: This branch’s 10 A fuse is rated the same as its upstream 10 A breaker. That does not demonstrate selective tripping; check actual fuse and breaker characteristics and supply conductor sizing before specifying replacement protection.

Survey backlog

Record the fitted fuse format and manufacturer, actual conductor size, supply/return wiring, and check appropriate protection coordination when the DC panel is replaced.

Record maintenance

  • Evidence: owner’s numbered fuse board inventory, 31 October 2026: way 1, 10 A, Icom M510 VHF.
  • This is an owner-confirmed as-installed inventory, not a physical wiring inspection or electrical compliance assessment.