Equipment Catalogue

Equipment records are listed in the Equipment Register. Status is generated directly from each equipment page; the catalogue does not maintain a separate copy. Mapped (U) means owner-confirmed identity and connections are documented, not independently electrically surveyed. U = identified, T = tentative, G = grouped. Keep passwords and other credentials out of this public website.

Equipment IDDescriptionDocumentation / survey status
EQ-065Garmin GPS 24xdU
EQ-066B&G WS310U
EQ-067B&G DST-810U
EQ-068Orca Core 2U
EQ-069B&G Triton 2 autopilot controllerU
EQ-070B&G Triton 2 MFD 1U
EQ-071B&G Triton 2 MFD 2U
EQ-072B&G Triton 2 MFD 3U
EQ-073B&G NAC-3U
CB-007NAV INSTR shared 10 A breakerU
EQ-075Companionway console clockU
EQ-074Yacht Devices “YD RA?” — model to confirmU
EQ-064Yacht Devices YDWG-02 wireless gatewayU
EQ-063NMEA 2000 segment A/B power isolatorU
EQ-059House-bank aggregated source interfaceMapped (U)
BB-003House-bank positive six-service distributionMapped (U)
BB-004DIY tinned-copper battery-negative linkMapped (U)
EQ-061Lewmar HX1 800 W windlassMapped (U)
EQ-062Windlass contactorMapped (U)
EQ-060Victron BMV-712 battery monitor and shuntMapped (U)
EQ-001Main DC panel (DCP)U
EQ-002NAV LTS four-breaker / yacht-outline panelMapped (U)
BB-001Main negative busbarU
BB-002DC panel negative busbarU
CB-001NAV masthead breaker, 10 AMapped (U)
CB-002NAV steaming breaker, 10 AMapped (U)
CB-00410 A deck-light breakerMapped (U)
CB-006Windlass fitted 70 A circuit breakerMapped (U)
CB-00510 A bow/stern navigation breakerMapped (U)
CB-003VHF AIS circuit breaker (10 A, position 3,4)Mapped (U)
SW-003Foredeck windlass control switch AMapped (U)
SW-004Foredeck windlass control switch BMapped (U)
SW-002House, Autopilot and Windlass shared remote battery switchMapped (U)
SW-001Masthead DPDT polarity-reversing selectorMapped (U)
TB-001DIN Y/R/B cage-clamp group 2U
TB-002DIN Y/R/B cage-clamp group 3U
TB-003Four-way connector blockU
EQ-003Icom IC-M510 VHF transceiverMapped (U)
EQ-004Ocean Signal ATB1 AIS transponderMapped (U)
EQ-005Digital Yacht SPL2000 AIS/VHF splitter (owner-confirmed)Mapped (U)
EQ-057COM-frame four-way FC fuse boardMapped (U)
FU-001COM-frame way 1: Icom M510 VHF, 10 AMapped (U)
FU-002COM-frame way 2: Digital Yacht SPL2000, 3 AMapped (U)
FU-003COM-frame way 3: Ocean Signal ATB1, 3 AMapped (U)
EQ-058Vesper Marine VA159 masthead VHF/AIS antennaMapped (U)
EQ-006Handheld VHF charging pointU
EQ-007Instrument-panel charging pointU
EQ-008Companionway charging pointU
EQ-009Pedestal magnetic-mount charging pointU
EQ-010Navigation-station cave charging point 1U
EQ-011Navigation-station cave charging point 2U
EQ-012Navigation-station cave charging point 3U
EQ-013Navigation-station cave charging point 4U
EQ-014Navigation-station hutch charging point 1U
EQ-015Navigation-station hutch charging point 2U
EQ-016Forward-cabin charging pointU
EQ-017Aft-cabin charging pointU
EQ-018Osculati bow bicolour LEDMapped (U)
EQ-019Osculati stern LED lightMapped (U)
EQ-020Osculati 13.243.88 combined steaming/deck LEDMapped (U)
EQ-021NASA Marine Combi masthead tricolour/anchor LEDMapped (U)
EQ-022Legacy deck-lights group (not an additional confirmed fitting)G
EQ-023Compass lightU
EQ-024Cockpit lightT
EQ-025Boom lightT
EQ-026Fresh-water supply pumpU
EQ-027Shower drain pumpU
EQ-028Fresh-water tank level sensorU
EQ-029Fresh-water level indicator panelU
EQ-030Bilge pump AT
EQ-031Bilge pump BT
EQ-032Engine compartment extractor fanU
EQ-033Engine compartment forward striplightU
EQ-034Engine compartment aft striplightU
EQ-035Engine compartment sensor nodeT
EQ-036RUTX50 routerU
EQ-037LAN network switchU
EQ-038Odroid N2 computerU
EQ-039LAN monitorU
EQ-040TRB500 mobile network deviceU
EQ-04130 W PoE injectorU
EQ-042Starlink terminalU
EQ-043150 W PoE injectorU
EQ-044TVU
EQ-045Radio / media playerT
EQ-046Forward-cabin downlights (group)G
EQ-047Saloon downlights (group)G
EQ-048Saloon starboard bunk reading light / USBU
EQ-049Saloon port bunk reading light / USBU
EQ-050Aft-cabin downlights (group)G
EQ-051Aft-cabin striplightU
EQ-052Aft-cabin port bunk reading light / USBU
EQ-053Aft-cabin other bunk reading light / USBU
EQ-054Heads striplightU
EQ-055Navigation-station red/white striplightU
EQ-056Galley striplightU

FU-003 — COM-frame fuse way 3, 3 A, Ocean Signal ATB1

← Equipment Register · COM fuse board · Circuit Register

Owner-confirmed installed fuse position, rating and protected equipment. Physical fuse format, make, condition and conductor size have not been independently surveyed.

FieldConfirmed record
Permanent fuse IDFU-003
Physical assemblyEQ-057 four-way fuse board
LocationSL-COM — COM frame
Physical position / way3 (owner numbering)
Installed fuse rating3 A (owner-confirmed)
Protected branch circuitDC-COM-04
LoadEQ-004 — Ocean Signal ATB1
Upstream protectionCB-003 10 A, through feeder DC-COM-01
Fuse type, time-current curve and manufacturerNot recorded
Branch cable cross-section, length and returnNot recorded

Protection distinction: FU-003 protects the DC-COM-04 branch conductor; CB-003 protects the upstream DC-COM-01 feeder. Coordination/discrimination and cable adequacy have not yet been assessed.

SW-001 — Masthead anchor/tricolour polarity selector

← Equipment Register · Browse equipment

Owner-confirmed function, not independently continuity-tested. The DPDT On-Off-On selector reverses supply polarity from the 10 A masthead breaker CB-001 to the NASA Marine Combi tricolour/anchor LED (EQ-021). Legacy 1–6 switch contacts remain to be electrically checked. NAV lighting diagram.

Identity and location

FieldValue
Permanent equipment IDSW-001
EquipmentMasthead anchor/tricolour polarity selector
Register categoryDC distribution and controls
Equipment classSW
Reported locationUnsurveyed
Inventory stateOwner-confirmed DPDT polarity switch; actual switch pinout not tested
Manufacturer / modelNot identified; owner survey required
Serial / part numberNot recorded
Last onboard verificationNot recorded

Original reference and notes: DPDT On-Off-On switch; source pin numbers 1–6; feeds combined masthead lamp.

SW-002 — Common House, Autopilot and Windlass remote battery switch

← Equipment Register · House DC distribution

Owner-confirmed switching topology: ONE remote switch controls House, Autopilot and Windlass together. Watchkeeper, Pump 1 and Pump 2 bypass it and remain available when the common switch is OPEN. Current physical switch model and wiring are not independently surveyed.

Identity / relationshipEvidence
Equipment IDSW-002
FunctionCommon remote ON/OFF contact for three distinct service circuits
SourceHouse positive bus BB-003
Windlass downstream controlLewmar HX1 EQ-061 is operated by contactor EQ-062 under two foredeck switches SW-003 / SW-004; distinct from this common upstream battery switch
Output branchesDC-HOU-01 House; DC-PIL-01 Autopilot; DC-WIN-01 Windlass
Unswitched pathsWatchkeeper and both pumps do not pass through this switch
Photographic evidenceOwner-supplied 5 August 2025 image of WhisperPower-branded DC Modular Remote Battery Switch, local OPEN/CLOSE buttons and control cable
Current model, continuous current ratingExact product code and markings not yet independently identified
Former design alternativeBEP 701-MD was later considered, not confirmed fitted

The owner confirms all original ANL and battery-post fuses were fitted and a separate 70 A windlass breaker CB-006 was retained. These are protective components, not separate remote switching contacts. They cannot be assigned to individual studs or protection positions from the 2025 photograph alone.

TB-001 — DIN cage-clamp connector group 2

← Equipment Register · Connector naming convention · Navigation-light circuits

Physical grouping and connector naming owner-confirmed; panel-end cable-core identities now supported by the owner’s photographed handwritten schedule, but the electrical connections have not been independently continuity-traced. These are individual generic cage-clamp connectors, arranged as a physical group with lever colours Yellow → Red → Blue behind the DC panel. The earlier rail photograph is incomplete. The owner has now also supplied a handwritten connector schedule identifying the panel-end cores of an Oceanflex 7 × 1.5 mm² cable to the forecabin starboard locker. That newer source establishes conductor assignments, not continuity or the physical onward branch topology. Schedule.

TB-002 — DIN cage-clamp connector group 3

← Equipment Register · Connector naming convention · Navigation-light circuits

Physical grouping and connector naming owner-confirmed; panel-end cable-core identities now supported by the owner’s photographed handwritten schedule, but the electrical connections have not been independently continuity-traced. These are individual generic cage-clamp connectors, arranged as a physical group with lever colours Yellow → Red → Blue behind the DC panel. The earlier rail photograph is incomplete. The owner has now also supplied a handwritten connector schedule identifying the panel-end cores of an Oceanflex 7 × 1.5 mm² cable to the forecabin starboard locker. That newer source establishes conductor assignments, not continuity or the physical onward branch topology. Schedule.

TB-003 — Four-way connector block

← Equipment Register · Browse equipment

Survey status: Listed, not physically verified. This record originates from the older DC Logical Circuits notes. It is not a verified-as-built electrical drawing. Model specifications are manufacturer reference information, not measured onboard data.

Identity and location

FieldValue
Permanent equipment IDTB-003
EquipmentFour-way connector block
Register categoryDC distribution and controls
Equipment classTB
Reported locationUnsurveyed
Inventory stateListed, not physically verified
Manufacturer / modelNot identified; owner survey required
Serial / part numberNot recorded
Last onboard verificationNot recorded

Original reference and notes: Source notes a 4-way connector on the DPDT 2 to DC-BB-A path; verify identity/location.