← Equipment Register · Windlass power circuit · House DC distribution
Owner-confirmed installed model (1 November 2026): Lewmar HX1 800 W. This identifies Ragtime’s physical windlass, but does not certify its electrical wiring, gypsy size, chain compatibility, serial number or condition. The original 2025 DC panel design article also identifies an HX1.
Equipment and connections
| Field | Recorded evidence |
|---|
| Equipment ID | EQ-061 |
| Manufacturer and model | Lewmar HX1, 800 W, 12 V; owner-confirmed fitted |
| Installation location | Foredeck, at the bow/anchor locker; exact physical mounting measurements not recorded |
| Source and power circuit | DC-WIN-01, on the house-bank common remotely switched supply SW-002 |
| Fitted circuit breaker | 70 A CB-006, owner-confirmed, not the previously misreported 80 A |
| Other distribution protection | Owner confirms ANL and battery-post fuses installed. The 2025 article specified 100 A ANL Windlass, which is a historical nominal specification until the fitted fuse marking is read |
| Windlass motor operation | Separate EQ-062 contactor, actuated by two switches on the foredeck, SW-003 and SW-004 |
| Low-current controls | DC-WIN-02 is the functional command/control path; actual fuse, control cable, directional mapping and contactor coil wiring untraced |
| Motor supply and negative return | Conductor cross-section, total circuit length, termination and actual BMV-712 system-side return not physically surveyed |
| Chain/gypsy and service | Gypsy and chain dimensions, clutch details, chain counter and maintenance history not yet recorded |
Manufacturer reference, not an onboard measurement
Lewmar’s HX1 installation, operation and servicing manual — document 65140050, Issue 2 specifies for the HX1 800: nominal 800 W/12 V model, 60 A current at working load, a supplied 70 A breaker (part 68000240), and 25 mm² cable guidance for a 20 m complete positive-and-negative electrical loop. Its standard wiring diagram includes a contactor (part 68000939), 3 A control fuse and 1.5 mm² control wiring. These are manufacturer specifications; the owner’s current confirmation is specifically the HX1 800 W, the fitted 70 A breaker and separate contactor with two foredeck switches. Do not infer that the installed contactor, fuse, switch parts or cable sections match the published standard drawing without tracing.