SW-001 — Masthead anchor/tricolour polarity selector

← Equipment Register · Browse equipment

Owner-confirmed function, not independently continuity-tested. The DPDT On-Off-On selector reverses supply polarity from the 10 A masthead breaker CB-001 to the NASA Marine Combi tricolour/anchor LED (EQ-021). Legacy 1–6 switch contacts remain to be electrically checked. NAV lighting diagram.

Identity and location

FieldValue
Permanent equipment IDSW-001
EquipmentMasthead anchor/tricolour polarity selector
Register categoryDC distribution and controls
Equipment classSW
Reported locationUnsurveyed
Inventory stateOwner-confirmed DPDT polarity switch; actual switch pinout not tested
Manufacturer / modelNot identified; owner survey required
Serial / part numberNot recorded
Last onboard verificationNot recorded

Original reference and notes: DPDT On-Off-On switch; source pin numbers 1–6; feeds combined masthead lamp.

Electrical installation — as fitted

FieldSurveyed value
Supply voltage / inputNot measured or recorded
Source / distribution busbarNot established
Circuit identifierDC-NAV-01 — selector on masthead circuit
Primary branch protective deviceNot confirmed
Upstream protective deviceNot confirmed
Cable / terminal referencesSee source notes and connections below; unverified until traced
Cable size, fuse/breaker rating and measured loadNot recorded

Important: a device’s manufacturer-rated input, current or recommended fuse is not proof of the actual cable, protection or wiring aboard Ragtime.

Known or reported relationships

  • CB-001 — reported supply breaker 1,1
  • EQ-021 — polarity-reversing masthead lamp
  • TB-003 — reported four-way connector

Corrected as-fitted connections (owner, 31 October 2026): SW-001 switches both the brown (R3) and white (B4) cores of the 7 × 1.5 mm² Oceanflex trunk, which continue through the forecabin locker into a separate Oceanflex 2 × 1.5 mm² mast cable supplying NASA Combi EQ-021. Neither switched leg is a permanently connected −12 V return, including any black-insulated conductor in the two-core mast cable. The original handwritten NC marks for R3/B4 and old B2/Y3 DPDT assignments have been superseded by the owner’s clarification; the source notes are preserved in the connector schedule.

The old drawing’s switch pins 1–6 and mode truth table have not been continuity-tested; the physical mapping from individual mast-cable conductor colours to brown versus white is not recorded.

Manufacturer reference

Make and model not yet reliably established. Manufacturer electrical specifications and the applicable PDF user/installation manual cannot safely be selected until the owner confirms the model.

Documentation: No model-specific PDF manual linked yet.

Information requested from the owner

  1. Verify the six-pin DPDT On-Off-On contact map and its physical location; the two switched trunk cores R3/brown and B4/white are owner-confirmed.
  2. Verify which NASA tricolour/anchor operating mode corresponds to each switch position and polarity. Do not assume the old pin numbering is electrically verified.

Record maintenance

  • Evidence basis: existing website inventory, plus explicitly identified manufacturer references where applicable.
  • Verification: pending physical survey; photograph, nameplate data and protective-device references to be recorded.