SW-002 — Common House, Autopilot and Windlass remote battery switch
← Equipment Register · House DC distribution
Owner-confirmed switching topology: ONE remote switch controls House, Autopilot and Windlass together. Watchkeeper, Pump 1 and Pump 2 bypass it and remain available when the common switch is OPEN. Current physical switch model and wiring are not independently surveyed.
| Identity / relationship | Evidence |
|---|---|
| Equipment ID | SW-002 |
| Function | Common remote ON/OFF contact for three distinct service circuits |
| Source | House positive bus BB-003 |
| Windlass downstream control | Lewmar HX1 EQ-061 is operated by contactor EQ-062 under two foredeck switches SW-003 / SW-004; distinct from this common upstream battery switch |
| Output branches | DC-HOU-01 House; DC-PIL-01 Autopilot; DC-WIN-01 Windlass |
| Unswitched paths | Watchkeeper and both pumps do not pass through this switch |
| Photographic evidence | Owner-supplied 5 August 2025 image of WhisperPower-branded DC Modular Remote Battery Switch, local OPEN/CLOSE buttons and control cable |
| Current model, continuous current rating | Exact product code and markings not yet independently identified |
| Former design alternative | BEP 701-MD was later considered, not confirmed fitted |
The owner confirms all original ANL and battery-post fuses were fitted and a separate 70 A windlass breaker CB-006 was retained. These are protective components, not separate remote switching contacts. They cannot be assigned to individual studs or protection positions from the 2025 photograph alone.
Remaining inspection
Read switch model, main contacts and remote-control wiring; locate the common output, three separately protected circuits, fitted ANL fuses, windlass 70 A breaker and three bypass feeds. Confirm actual switch status feedback and local manual operation before treating this as a verified electrical schematic.