Physical grouping and connector naming owner-confirmed; panel-end cable-core identities now supported by the owner’s photographed handwritten schedule, but the electrical connections have not been independently continuity-traced. These are individual generic cage-clamp connectors, arranged as a physical group with lever colours Yellow → Red → Blue behind the DC panel. The earlier rail photograph is incomplete. The owner has now also supplied a handwritten connector schedule identifying the panel-end cores of an Oceanflex 7 × 1.5 mm² cable to the forecabin starboard locker. That newer source establishes conductor assignments, not continuity or the physical onward branch topology. Schedule.
Identity and physical references
| Field | Recorded information |
|---|---|
| Equipment documentation ID | TB-001 |
| Function of this record | Physical connector group 2, not a single electrically common three-way terminal |
| Location | Behind original main DC panel, CT-R (chart-table panel rear) |
| Three individual connectors | Y2, R2, B2 — distinct colour-lever clamp positions |
| Group sequence | Repeating Yellow / Red / Blue connectors; group 2 counted from the top |
| Make and model | Generic Chinese cage-clamp connectors; specific manufacturer/model and ratings unknown |
| Survey status | Owner confirms physical naming/grouping, no photo of complete rail and no independent continuity measurements |
Naming rule: The letter is the lever colour and the digit is the group ordinal. It is not the colour of the attached wire, nor an identifier for a three-way electrically linked assembly. Do not assume these three positions are bridged.
Handwritten panel-end allocations (not independently continuity-tested)
| Clamp alias | Original wiring note | Status |
|---|---|---|
Y2 (yellow lever) | Yellow core of Oceanflex 7 × 1.5 mm² forecabin trunk, handwritten STEAM. | Panel-end cable core documented; onward mast pigtail connection untraced |
B2 (blue lever) | Blue core of Oceanflex 7 × 1.5 mm² forecabin trunk, handwritten MAST HD | Panel-end cable core documented; downstream selector/mast connections untraced |
R2 (red lever) | Red core of Oceanflex 7 × 1.5 mm² forecabin trunk, handwritten DECK | Panel-end connection documented; downstream deck-light branch untraced |
This is an indexed physical reference, not a verified as-fitted wiring test. The panel-end conductor identities come from the owner’s handwritten schedule, with functional descriptions also preserved from the older DC Logical Circuits notes. The photo of the rail is incomplete, and the downstream locker distribution has not been traced.
Information still needed
- Identify the actual conductor occupying each referenced clamp and any bridging/jumper arrangement; no connection is assumed for unnamed clamps.
- Record any conductor cross-section, clamp manufacturer/type/current rating and terminals during access to the back of the DC panel.
- Trace B2, Y2, R2 through the forecabin starboard-locker distribution and independent onward runs. Handwritten panel schedule.
Record maintenance
- 31 October 2026: owner confirmed repeated Y/R/B individual cage-clamp groups and
<lever colour><group number>notation. Photo supplied is incomplete. - Existing mast conductor and device relationships remain legacy-noted, not electrically verified.