Configuration

Electrical systems

DC-COM-02 — Icom M510 VHF power

← Circuit Register · COM-frame diagram · Fuse equipment

Owner-confirmed branch assignment and fuse rating. The physical conductor, terminations and return path have not been independently surveyed.

FieldValue
Circuit identifierDC-COM-02
SourceEQ-057 four-way fuse board on the COM frame
Primary branch protectionFU-001, 10 A, fuse position 1
LoadEQ-003 — Icom M510 VHF
Upstream feederDC-COM-01, protected by CB-003 10 A
Branch conductor/returnType, cross-section, length, termination and routing not yet confirmed
Evidence statusOwner-confirmed load, fuse way and ampere rating; wiring not independently traced

Protected circuit: This fuse protects the conductor from position 1 of EQ-057 to Icom M510 VHF. The upstream 10 A CB-003 feeder protection is separate.

DC-COM-03 — Digital Yacht SPL2000 power

← Circuit Register · COM-frame diagram · Fuse equipment

Owner-confirmed branch assignment and fuse rating. The physical conductor, terminations and return path have not been independently surveyed.

FieldValue
Circuit identifierDC-COM-03
SourceEQ-057 four-way fuse board on the COM frame
Primary branch protectionFU-002, 3 A, fuse position 2
LoadEQ-005 — Digital Yacht SPL2000
Upstream feederDC-COM-01, protected by CB-003 10 A
Branch conductor/returnType, cross-section, length, termination and routing not yet confirmed
Evidence statusOwner-confirmed load, fuse way and ampere rating; wiring not independently traced

Protected circuit: This fuse protects the conductor from position 2 of EQ-057 to Digital Yacht SPL2000. The upstream 10 A CB-003 feeder protection is separate.

DC-COM-04 — Ocean Signal ATB1 power

← Circuit Register · COM-frame diagram · Fuse equipment

Owner-confirmed branch assignment and fuse rating. The physical conductor, terminations and return path have not been independently surveyed.

FieldValue
Circuit identifierDC-COM-04
SourceEQ-057 four-way fuse board on the COM frame
Primary branch protectionFU-003, 3 A, fuse position 3
LoadEQ-004 — Ocean Signal ATB1
Upstream feederDC-COM-01, protected by CB-003 10 A
Branch conductor/returnType, cross-section, length, termination and routing not yet confirmed
Evidence statusOwner-confirmed load, fuse way and ampere rating; wiring not independently traced

Protected circuit: This fuse protects the conductor from position 3 of EQ-057 to Ocean Signal ATB1. The upstream 10 A CB-003 feeder protection is separate.

DC-HOU-01 — House — remotely switched supply

← Circuit Register · House-bank supply diagram

Owner-reported circuit purpose; electrical installation not independently surveyed. Owner-confirmed House circuit, controlled together with Autopilot and Windlass by one common remote switch SW-002; feeder protection, cable size and actual switch output splitting untraced.

FieldRecord
CircuitDC-HOU-01
SourceBB-003 positive distribution
Function / destinationMain Moody chart-table DC panel EQ-001 and downstream house services
Functional controlSW-002 common remote switch; House, Autopilot and Windlass simultaneously ON/OFF, Watchkeeper and both pumps unaffected
Installed branch fuse / breakerOriginal ANL fusing installed per owner, exact service allocation and value not independently verified
Source protection / isolationUnknown; input connection to source and upstream protection not surveyed
Cable and return pathConductor size, route, overcurrent coordination, negative return through the BMV-712 system-side shunt terminal unverified

This circuit is a functional link, not evidence that a correctly rated protective device has been inspected. The service’s switching state, its fusing and its protective role are independent properties. The unswitched circuits remain live while the common SW-002 House/Autopilot/Windlass switch is OFF; do not interpret unswitched as unprotected.

DC-PIL-01 — Autopilot — remotely switched supply

← Circuit Register · House-bank supply diagram

Owner-reported circuit purpose; electrical installation not independently surveyed. Owner-confirmed separate Autopilot supply circuit, but controlled together with House and Windlass by the one common remote switch SW-002. Breaker/fuse rating and downstream wiring unverified.

FieldRecord
CircuitDC-PIL-01
SourceBB-003 positive distribution
Function / destinationAutopilot distribution: NAC-3 and steering drive related equipment, protected subcircuits not yet allocated
Functional controlSW-002 common remote switch, simultaneously controlling Autopilot, House and Windlass; NOT independent remote isolation
Installed branch fuse / breakerOriginal ANL fusing installed per owner, precise branch allocation and nominal value not independently verified
Source protection / isolationUnknown; input connection to source and upstream protection not surveyed
Cable and return pathConductor size, route, overcurrent coordination, negative return through the BMV-712 system-side shunt terminal unverified

This circuit is a functional link, not evidence that a correctly rated protective device has been inspected. The service’s switching state, its fusing and its protective role are independent properties. The unswitched circuits remain live while the common SW-002 House/Autopilot/Windlass switch is OFF; do not interpret unswitched as unprotected.

DC-PWR-01 — House-bank source to positive distribution

← Circuit Register · House-bank supply diagram

Owner-reported circuit purpose; electrical installation not independently surveyed. Owner-confirmed source-to-positive bus topology; battery-post fuses owner-confirmed fitted, but their exact ratings/positions, isolation, conductor sizes and rated ampacity unverified.

FieldRecord
CircuitDC-PWR-01
SourceEQ-059 house-bank positive source
Function / destinationBB-003 positive distribution feeding six functional services
Functional controlunspecified upstream source isolation; never assume the five downstream circuits are individually fused simply because they have five destinations
Installed branch fuse / breakerBattery-post MRBF fusing owner-confirmed fitted; July 2025 design stated 2 × 125 A, current device markings not inspected
Source protection / isolationBattery-post protection exists per owner; main isolation and fuse positions/values not physically surveyed
Cable and return pathConductor size, route, overcurrent coordination, negative return through the BMV-712 system-side shunt terminal unverified

This circuit is a functional link, not evidence that a correctly rated protective device has been inspected. The service’s switching state, its fusing and its protective role are independent properties. The unswitched circuits remain live while the House or Autopilot remotely switched feeds are OFF; do not interpret unswitched as unprotected.